High Flexibility Polycaprolactone Polymer NMPA Poly-L-Lactic Acid
Basic Properties
Place of Origin:
CHINA
Brand Name:
FITAKH
Certification:
NMPA ISO13485 GMP
Model Number:
PCL02
Trading Properties
Minimum Order Quantity:
1
Price:
40USD
Payment Terms:
T/T
Supply Ability:
100000
Specifications
| Formulation: | Biocompatible, Biodegradable Microspheres | Onsetofresults: | Gradual, Noticeable Improvement Within Weeks |
| Numberofsessions: | Typically 2-3 Sessions Spaced 4-6 Weeks Apart | Storageconditions: | Store At 2-25°C, Protect From Light |
| Activeingredient: | Poly-L-Lactic Acid (PLLA) | Indications: | Treatment Of Facial Lipoatrophy, Nasolabial Folds, And Other Facial Wrinkles |
| Safetyprofile: | Low Risk Of Allergic Reaction, Non-immunogenic | Durationofeffect: | Up To 2 Years |
| Commonsideeffects: | Mild Swelling, Redness, Bruising At Injection Site | Contraindications: | Active Skin Infections, Allergy To PLLA Components, Pregnancy, Breastfeeding |
| Purpose: | Facial Volume Restoration And Wrinkle Reduction | Productname: | PLLA Dermal Filler |
| Injectiontechnique: | Deep Dermal Or Subcutaneous Injection | Type: | Injectable Dermal Filler |
| High Light: | High Flexibility Polycaprolactone Polymer,Polycaprolactone Polymer NMPA,NMPA Poly-L-Lactic Acid |
||
Product Description
High Flexibility PCL Polymer with Professional Performance and Complete Technical Parameters for Medical Aesthetic Products
PCL Polymer
|
Technical Item
|
Specification
|
|---|---|
|
Chemical Name
|
Polycaprolactone (PCL)
|
|
Molecular Weight
|
30,000–80,000 Da (customizable)
|
|
Melting Point
|
58℃–62℃
|
|
Glass Transition Temperature
|
-60℃
|
|
Purity
|
≥99.5% Medical Grade
|
|
Degradation Cycle
|
12–24 months (human body environment)
|
|
Biocompatibility Grade
|
ISO 10993 Certified
|
2. Key Product Performance
-
Superior Flexibility & Ductility: PCL is a semi-crystalline aliphatic polyester with ultra-low glass transition temperature. It maintains soft and tough physical properties at room and body temperature, featuring excellent flexibility and tensile ductility. Unlike rigid polymer materials, it can adapt to human skin and tissue stretching without hardening or foreign body sensation, ensuring comfortable and natural application effect.
-
Controllable Slow Degradability: The material possesses stable and uniform hydrolysis performance. It degrades slowly and evenly in physiological environments through ester bond hydrolysis, avoiding rapid volume loss or local collapse. The complete degradation cycle is moderate and predictable, perfectly matching the cycle of human tissue repair and collagen regeneration.
-
Excellent Biocompatibility & Safety: Medical-grade PCL has ultra-high purity with no toxic monomers or harmful residues. It will not cause immune rejection, inflammation or allergic reactions after implantation. The final degradation products are carbon dioxide and water, which can be completely metabolized by the human body, meeting strict medical safety standards.
-
Outstanding Processability & Compatibility: With low melting point and good fluidity, PCL is suitable for microsphere preparation, electrospinning and injection molding. It can be perfectly blended with PLLA, HA and other materials to adjust hardness and degradation speed, meeting diversified customization needs for medical aesthetic fillers and tissue engineering materials.